CASTECH
Diffraction Gratings for Pulse Compression
+
  • Diffraction Gratings for Pulse Compression

Diffraction Gratings for Pulse Compression

Chirped Pulse Amplification (CPA) is widely used in lasers to generate ultrashort and high-energy pulses. In pulse stretching and compression systems, gratings are one of the most critical components determining performance.

Keyword:

Optical Diffraction Grating pulse compression pulse stretch

Diffraction Gratings for Pulse Compression

  • Description
  • Cas'Tech Class
  • Parameters
  • ► Typical Dimensions: 110 × 30 × 16 mm (customizable) 
    ► Dimensional Tolerance: ±0.1 mm 
    ► Clear Aperture: >106 × 26 mm 
    ► Diffraction Efficiency: ≥94% 
    ► Line Density: 1700.7 ± 0.5 line/mm 
    ► Angle of Incidence: 61.7° (Littrow configuration) 
    ► Central Wavelength: 1035 nm 
    ► Polarization: P-polarization or S-polarization 
    ► Grating Line Perpendicularity: 90° ± 12′ 
    ► Grating Orientation: Parallel to the substrate long edge 
    ► Diffracted Wavefront: <λ @ 633 nm 
    ► Surface Quality: Standard: 60/40, customize: 40/20 or 20/100

    Chirped Pulse Amplification (CPA) is widely used in lasers to generate ultrashort and high-energy pulses. In pulse stretching and compression systems, gratings are one of the most critical components determining performance. CASTECH's gold-coated reflective gratings and 100% dielectric transmissive gratings are fabricated using holographic or projection lithography combined with advanced reactive ion beam etching technology. These gratings feature low scattering, high diffraction efficiency, and high cost-effectiveness, and have been successfully applied in laser pulse stretching and compression. CASTECH provides customized solutions, including prototype development and volume production

    Reliability Testing

    GratingMaterialTestItemTestConditions
    DielectricGrating/Gold-CoatedGratingTemperatureCyclingTest-40 °Cto85 °C,dwelltime:15min,cycles:1000
    DielectricGratingDampHeatTest85 ± 2 °C85 ± 5%RH,2000hours
    DielectricGrating/Gold-CoatedGratingDryHeatTest85 ± 2 °C&40%RH,2000hours

    Detection Capability

    Projection Exposure Equipment

    RIE-ICP etching machine

    Agilent Tunable Laser

    Key words:
    • Optical Diffraction Grating
    • pulse compression
    • pulse stretch

Inquiry List

Submit